BPGVY - 8031, WELDERS ANTI SPATTER
- MSDS: BPGVY
- Manufacturer: CROWN INDUSTRIAL PRODUCTS CO INC
- Product Name: 8031, WELDERS ANTI SPATTER
- National Stock Number: 6850-00N030914
Product Identification
Product ID:8031, WELDERS ANTI SPATTER
MSDS Date:07/28/1986
FSC:6850
NIIN:00N030914
MSDS Number: BPGVY
Responsible Party
HEBRON, IL 60034
US
Emergency Phone: 815-648-2424;815-338-2141
Info Phone: 815-648-2424
Preparer: ROBERT E. BAYTON
Cage: 92381
Contractor
Telephone: 815-648-2424
Cage: 92381
Ingredients
METHANE, DICHLORO-;(METHYLENE CHLORIDE)
CAS: 76-13-1
RTECS: KJ4000000
Fraction By Weight: 31-50%
OSHA PEL 1000 PPM;1250 STEL
ACGIH TLV: 1000 PPM;1250 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
CARBON DIOXIDE
CAS: 124-38-9
RTECS: FF6400000
Fraction By Weight: 1-10%
OSHA PEL 5000 PPM
ACGIH TLV: 5000PPM/30000STEL;93
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:SHORTNESS OF BREATH,
DIZZINESS, LIGHT HEADEDNESS. ANESTHETIC EFFECTS MAY OCCUR AT HIGH
CONCENTRATIONS. INGEST:MAY CAUSE CHEMICAL PNEUMONIA IF ASPIRATED
INTO LUNGS. EYE:POSSIBLE IRRITANT. S KIN:SHORT CONTACT:NO
IRRITATION. PROLONGED OR REPEATED CONTACT: MINOR TO MILD IRRIT.
SKIN ABSORPTION:(EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE:GROUP 2 (NTP), GROUP
2B (IARC).
Effects of Overexposure:HLTH HAZ:VERY LOW TOXICITY. CHLOROCARBON/
CHLOROFLUOROCARBON (CFC) MATERIALS HAVE PRODUCED SENSITIZATION OF
THE MYOCARDIUM TO EPINEPHRINE TO IN LAB ANIMALS & COULD HAVE
SIMILAR EFFECT IN HUMANS. ADREN OMIMETICS (E.G., EPINEPHRINE) MAY
BE CONTRA-INDICATED EXCEPT FOR LIFE SUSTAINING USES IN HUMANS
ACUTELY OR (SUDAT)
Medical Cond Aggravated by Exposure:MAY CAUSE MYOCARDIAL IRRITABILITY.
AVOID EPINEPHRINE OR SIMILAR DRUGS IF AT ALL POSSIBLE.
First Aid
First Aid:CALL MD. EYE:FLUSH WITH WATER FOR AT LEAST 15 MINUTES OR
UNTIL IRRITATION SUBSIDES. SKIN:REMOVE ALL CONTAMINATED CLOTHING
AND WASH SKIN WITH SOAP & WATER. INHAL:MOVE FROM EXPOSURE
IMMEDIATELY. IF BREA THING IRREGULAR OR STOPPED BEGIN ARTIFICIAL
RESPIRATION AND GIVE OXYGEN. INGEST:DRINK LARGE AMOUNTS OF WATER.
DO NOT INDUCE VOMITING.
Fire Fighting
Flash Point Method:TCC
Flash Point:NONE
Lower Limits:14.8%
Upper Limits:22%
Extinguishing Media:WATER FOG, BUT NOT FLAMMABLE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:TREAT AS CYLINDERS OF COMPRESSED GAS.
THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE CHLORIDES, FLUORIDES AND
PHOSGENE .
Accidental Release
Spill Release Procedures:VENTILATE AREA. REMOVE ALL SOURCES OF
IGNITION. CLEAN UP WITH INERT MATERIALS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT SPRAY AROUND OPEN FLAMES OR
SPARKS. EXPOSURE TO HEAT OR SUNLIGHT OR WHERE TEMPERATURES EXCEED
120F MAY CAUSE BURSTING.
Other Precautions:AVOID SKIN CONTACT. USE ONLY AS DIRECTED. INTENTIONAL
MISUSE BY DELIB CONC VAPS MAY BE HARMFUL/FATAL. NO SMKNG IN AREA OF
USE. DO NOT USE IN GEN VICIN OF ARC WELDING, OPEN FLAMES OR HOT
SURFS. HEAT &/ OR UV RADIA MAY CAUSE FORMATION (SUPDAT)
Exposure Controls
Respiratory Protection:RESPIRATORY PROGRAMS SHOULD BE IN ACCORDANCE
WITH 29 CFR 1910.134. NIOSH/MSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST IS ADEQUATE.
Protective Gloves:POLYETHYLENE OR NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE CLOTHING AND EQUIPMENT:SEE 29 CFR
1910.132 & 133.
Work Hygienic Practices:WASH SKIN WITH SOAP & WATER.
Supplemental Safety and Health
HMIS(LEVIEN) HAS ASSIGNED HCC OF G1 BASED ON METHYLENE
CHLORIDE(POISON,6.1,III)/CARBON DIOXIDE(GAS,2.2)..VP:85-95 PSIG
(AEROSOL). EFTS OF OVEREXP: CHRONICALLY EXPOSED TO CHLOROCARBONS OR
CFC'S. CHRONI C:PROLONGED EXPOUSRE MAY RESULT IN KIDNEY AND LIVER
DAMAGE. OTHER PREC:OF CHLORIDES, FLUORIDES AND PHOSGENE .
Chemical Properties
HCC:G1
Vapor Pres:SUPP DATA
Vapor Density:>1
Spec Gravity:>1
Evaporation Rate & Reference:<1 (ETHER=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR COLORLESS/ETHEREAL ODOR
Percent Volatiles by Volume:>97
Stability
Stability Indicator/Materials to Avoid:YES
AMINES, SODIUM, POTASSIUM, ALUMINUM, BERYLIUM AND MAGNESIUM.
Stability Condition to Avoid:OPEN FLAMES, SPARKS, ELECTRICAL ARCS.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY YIELD HCL,
SMALL AMOUNTS OF PHOSGENE & CHLORINE. FLUORIDES .
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE,
AND FEDERAL REGULATIONS. AEROSOL CONTAINERS:DO NOT PUNCTURE OR
INCINERATE. EMPTY CONTAINERS MAY BE DISPOSED OF THROUGH NORMAL
CHANNELS. FULL/PARTIALLY F ILLED CONTAINERS ARE CONSIDERED
HAZARDOUS WASTE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.